The Japan Academy

Personal Information

 

Name

SHIRATO Hiroki

 

Section

Section II, Seventh Subsection

Date of Election

2023/12/12

Speciality

Medicine, Biomedical Science and Engineering

Selected Bibliography

  1. Shirato, H, Mizuta, M, and Miyasaka, K: A mathematical model of the volume effect which postulates cell migration from unirradiated tissues. Radiother. Oncol., 35;227-231, 1995.
  2. Shirato, H, Shimizu, S, Shimizu, T, Nishioka, T, and Miyasaka, K: Real-time tumour-tracking radiotherapy. Lancet, 353:1331-1332, 1999.
  3. Shirato, H, Shimizu, S, Kunieda, T, Kitamura, K, van Herk, M, Kagei, K, Nishioka, T, Hashimoto, S, Fujita, K, Aoyama, H, Tsuchiya, K, Kudo, K, and Miyasaka K: Physical aspects of a real-time tumor-tracking system for gated radiotherapy. Int. J. Radiat. Oncol. Biol. Phys., 48;1187-1195, 2000.
  4. Shirato, H, Shimizu, S, Kitamura, K, Nishioka, T, Kagei, K, Hashimoto, S, Aoyama, H, Kunieda, T, Shinohara, N, Dosaka-Akita, H, and Miyasaka, K: Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. Int. J. Radiat. Oncol. Biol. Phys., 48; 435-442, 2000.
  5. Seppenwoolde, Y, Shirato, H, Kitamura, K, Shimizu, S, van Herk, M, Lebesque, JV, and Miyasaka K: Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int. J. Radiat. Oncol. Biol. Phys., 53; 822-834, 2002.
  6. Aoyama, H, Shirato, H, Tago, M, Nakagawa, K, Toyoda, T, Hatano, K, Kenjyo, M, Oya, N, Hirota, S, Shioura, H, Kunieda, E, Inomata, T, Hayakawa, K, Katoh, N, and Kobashi, G: Stereotactic radiosurgery plus whole-brain radiation therapy vs stereotactic radiosurgery alone for treatment of brain metastases: a randomized controlled trial. J.A.M.A., 295;2483-2491, 2006.
  7. Shirato H, Suzuki K, Sharp GC, Fujita K, Onimaru R, Fujino M, Kato N, Osaka Y, Kinoshita R, Taguchi H, Onodera S, Miyasaka K. Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy. Int. J. Radiat. Oncol. Biol. Phys.,64;1229-1236. 2006.
  8. Mizuta M, Takao S, Date H, Kishimoto N, Sutherland KL, Onimaru R, Shirato H: A mathematical study to select fractionation regimen based on physical dose distribution and the linear-quadratic model. Int. J. Radiat. Oncol. Biol. Phys., 84;829-833, 2012.
  9. Shimizu, S, Miyamoto, N, Matsuura, T, Fujii, Y, Umezawa, M, Umegaki, K, Hiramoto, K, and Shirato, H: A proton beam therapy system dedicated to spot-scanning increases accuracy with moving tumors by real-time imaging and gating and reduces equipment size. PLoS One, 9; e94971, 2014.
  10. Shirato H. Biomedical advances and future prospects of high-precision three-dimensional radiotherapy and four-dimensional radiotherapy. Proc. Jpn. Acad. Ser. B Phys. Biol. Sci., 99; 389-426, 2023.